TELEMETRY CABLE


The specification of the seismic cables provided by TALA have been qualified with accepted electricity and mechanical features, the same type cable can be interchangeable with imported cables. The cables series covered of different types as well as telemetry cable and analog cable, land cable and waterproof cable, or developing new type of cable according to client's required.

TELEMETRY CABLE TYPES
1.408Ul Cable SC4T/408UL WPSR SC4T/408UL ST
2.SN388 Cable
£¨F£©SC14T/2P/SN388 (F) SC10T/2P/SN388
£¨F£©SC12T/2P/SN388 (F) SC9T/4P/SN388
3£®G.DAPS£­4A Cable SC12T/2P/G.DAPS-4A
4£®ARAM/ARIES Cable SC16T/2P/LCC/ARIES
5£®SYSTEM I/II (2000) Cable SC16T SC22T SC20T£¯3P


Digital Seismic Cable for 408UL


Item SC4T/408UL ST SC4T/408UL WPSR
Type of field Dry Dive
Water blocking material no yes
Maximal operational depth Rainy 15m
Outside diameter 6.5mm 9.5mm
Minimum jacket thickness 1.4mm 1.4mm+1.2mm
Jacket material TPU TPU+TPU
Operating temperature range -40¡æ~+70¡æ -10¡æ~+70¡æ
Storage temperature range -55¡æ~+85¡æ -55¡æ~+85¡æ
Number of flexing ¡Ý30000 ¡Ý30000
Kevlar no yes
Weight 50kg/km 90kg/km
Pull 500N 4100N (With connector2500N)

   

TOP¡ü



Digital Seismic Cable for SN388


Item SC14T/2P FSC14T/2P FSC10T/2P SC9T/4P
Type of field Dry Dive Dive Dry
Water blocking material no yes yes no
Maximal operational depth Rainy 10m 10m Rainy
Outside diameter 10mm 10.5mm 8.2mm 10.5mm
Minimum jacket thickness 1.1mm 1.2mm 1mm 1.1mm
Jacket material TPU TPU TPU TPU
Operating temperature range -40¡æ~+70¡æ -40¡æ~+70¡æ -40¡æ~+70¡æ -40¡æ~+70¡æ
Storage temperature range -55¡æ~+85¡æ -55¡æ~+85¡æ -55¡æ~+85¡æ -55¡æ~+85¡æ
Number of flexing ¡Ý20000 ¡Ý20000 ¡Ý20000 ¡Ý15000
Kevlar yes yes yes no
Weight 103kg/km 1123kg/km 70kg/km 90kg/km
Pull 1100N 1100N 1200N 800N

   

TOP¡ü



Digital Seismic Cable for G.DAPS-4(A)


Item SC12T/2P/G.DAPS-4 FSC12T//2P/G.DAPS-4A
Type of field Dry Dive
Water blocking material no yes
Maximal operational depth Rainy 15m
Outside diameter 9.5mm 11.3mm
Minimum jacket thickness 1.1mm 1.6mm
Jacket material TPU TPU
Operating temperature range -40¡æ~+70¡æ -40¡æ~+70¡æ
Storage temperature range -55¡æ~+85¡æ -55¡æ~+85¡æ
Number of flexing ¡Ý20000 ¡Ý20000
Kevlar yes yes
Weight 55kg/km 110kg/km
Pull ¡Ý1000N ¡Ý3000N

   

TOP¡ü



Digital Seismic Cable for ARIES


Item SC12T/2P/LC FSC16T/2P/LCC SC16T/8P/MPC
Type of field Dry Dry Dry
Water blocking material no no no
Maximal operational depth Rainy Rainy Rainy
Outside diameter 7mm 8.5mm 9.3mm
Minimum jacket thickness 1.3mm 1.3mm 1.5mm
Jacket material TPU TPU TPU
Operating temperature range -40¡æ~+70¡æ -40¡æ~+70¡æ -40¡æ~+70¡æ
Storage temperature range -55¡æ~+85¡æ -55¡æ~+85¡æ -55¡æ~+85¡æ
Number of flexing ¡Ý10000 ¡Ý10000 ¡Ý10000
Kevlar yes yes yes
Weight 48kg/km 59kg/km 83kg/km
Pull 1450N 1700N 1700N

   

TOP¡ü



Digital Seismic Cable for I/O-SYSTEM-I/II (2000)


Item SC16T SC20T/3P SC22T
Type of field Dry Dry Dry
Water blocking material no no no
Maximal operational depth Rainy Rainy Rainy
Outside diameter 9mm 10.5mm 8.2mm
Minimum jacket thickness 1.6mm 1.6mm 1.1mm
Jacket material TPU TPU TPU
Operating temperature range -40¡æ~+70¡æ -40¡æ~+70¡æ -40¡æ~+70¡æ
Storage temperature range -55¡æ~+85¡æ -55¡æ~+85¡æ -55¡æ~+85¡æ
Number of flexing ¡Ý20000 ¡Ý30000 ¡Ý20000
Kevlar yes yes yes
Weight 75kg/km 134kg/km 90kg/km
Pull 2100N 1130N 2100N

   

TOP¡ü